Fuse box 2
From uCtrl.net
| This project/unit has been terminated or discontinued, article no longer maintained. |
FB2 installed in the Rack box
FB2.
Contents |
Information
FB1 has three 12V and 5V circuits, every circuit has fuses on both polarities and is monitored. Every pair of fuses supplies a optoisolator with positive and negative voltage. When both polarities are present the optoisolator will trigger the inverter. When the input of the inverter is triggered, the output will be inactive. If a fuse should break the optoisolator will cut the signal to the inverter, causing the output to be activated and a LED indicates which circuit is broken. All inverter outputs is connected to a OR gate that sends an alarm signal to MMU. FB2 also monitors and external fuse.
D-Sub 25-pin
- 5V fuse 1 +
- 5V fuse 1 -
- 5V fuse 2 +
- 5V fuse 2 -
- 5V fuse 3 +
- 5V fuse 3 -
- 5V fuse 4 +
- 5V fuse 4 -
- From LED power supply
- Alarm signal to MMU
- Signal from external fuse
Images
Connector in the Rack box |
|||
FB2 installed in the Rack box |